Accumulator Recharge
How to Recharge Accumulator on your Hydraulics system
WARNING – Accumulators must be charged slowly as nitrogen gas will freeze the rubber bladder if filled to quick causing it to crack and will be unable to hold pressure.

Step 1
Remove Red Cap.

Step 2
Remove black cap on gas charging valve.
Gas charging valve with black cap removed.

Step 3
Select the correct charging adaptor.

Step 4
Fit Charging adaptor to charging head. Ensure handle is unwound once adaptor has been fitted to charging head.

Step 5
Screw charging head and adaptor to gas charging valve on top of accumulator.

Step 6
Connect pressure gauge to Port A and feed hose from nitrogen bottle to Port B.

Step 7
Fit Feed hose and flow control to nitrogen bottle making sure the flow control valve is fully closed before fitting to bottle.

Step 8
-
-
-
-
-
- Turn handle on top of charging head Clockwaise to open valve.
- Open Nitrogen bottle main valve.
- Very slowly open flow control valve to allow accumulator to fill with nitrogen till required pressure is reached.
- Close flow control valve and nitrogen bottle main valve.
- Turn handle on charging head anticlockwise to close the gas valve on accumulator.
- Remove feed hose, gauge and charging head and replace black cap on valve.
- Replace red cap on accumulator.
-
-
-
-